Higher collateral damage found with pulsed-field ablation: 4 study notes

Advertisement

Collateral effects on non-target tissue are worse with pulsed-field ablation than with radiofrequency ablation, according to a study published April 24 in JACC: Clinical Electrophysiology

The multicenter study, led by researchers from the Kansas City (Kan.) Heart Rhythm Institute, analyzed data from 871 patients who underwent pulsed-field ablation or radiofrequency ablation beginning March 2024 and onward.

Here are four notes on the study:

  1. Of the 773 patients who underwent pulsed-field ablation, 70.9% were with a pentaspline system, 14.1% with a circular multielectrode, 12.4% with a spherical and 2.3% with a variable loop catheter.
  2. Post-procedural changes associated with pulsed-field ablation included higher levels of troponin, lactate dehydrogenase and haptoglobin biomarkers, compared to the levels associated with radiofrequency ablation.

    These changes were dose-dependent and varied across the pulsed-field ablation systems used.
  3. There was also significant change in left atrial ejection fraction associated with pulsed-field ablation compared to radiofrequency ablation, at -5.0% and -20.0%, respectively.
  4. “As [pulsed-field ablation] becomes mainstream, future studies appraising these effects and understanding the short term and long-term implications are needed,” the study authors wrote. 

Read the full study here

At the Becker's 23rd Annual Spine, Orthopedic and Pain Management-Driven ASC + The Future of Spine Conference, taking place June 11-13 in Chicago, spine surgeons, orthopedic leaders and ASC executives will come together to explore minimally invasive techniques, ASC growth strategies and innovations shaping the future of outpatient spine care. Apply for complimentary registration now.